MB006
heag171-176_mb (13A1)
10
9.1 Electrical data
• Transmissionlength: ≤300m
HEAG 171
• Voltage supply: 9...26 VDC
5 VDC ±5 %
• Consumption: ≤200mA
• Inputs: 4 x TTL
• Input signals: K1, K2, K3, K4 + inv.
• Outputs: 4xfiberoptic
• Output signals: Fiber optic 1, 2, 3, 4
HEAG 172
• Voltage supply: 9...26 VDC
• Consumption: ≤200mA
• Inputs: 4 x HTL
• Input signals: K1, K2, K3, K4 + inv.
• Outputs: 4xfiberoptic
• Output signals: Fiber optic 1, 2, 3, 4
HEAG 173
• Voltage supply: 5 VDC ±5 %
• Consumption: ≤60mA
• Inputs: 3xfiberoptic
• Input signals: Fiber optic 1, 2, 3
• Outputs: 3 x TTL
• Output signals: K1, K2, K3 + inv.
HEAG 174
• Voltage supply: 9...26 VDC
• Consumption: ≤60mA
• Inputs: 3xfiberoptic
• Input signals: Fiber optic 1, 2, 3
• Outputs: 3 x HTL
• Output signals: K1, K2, K3 + inv.
HEAG 175
• Voltage supply: 9...26 VDC
5 VDC ±5 %
• Consumption: ≤200mA
Technical data 9
• Inputs: 3 x TTL
• Input signals: K1, K2, K3 + inv.
• Outputs: 3xfiberoptic
• Output signals: Fiber optic 1, 2, 3
HEAG 176
• Voltage supply: 9...26 VDC
• Consumption: ≤200mA
• Inputs: 3 x HTL
• Input signals: K1, K2, K3 + inv.
• Outputs: 3xfiberoptic
• Output signals: Fiber optic 1, 2, 3
9.2 Mechanical data
HEAG 171, HEAG 172
• Dimensions
W x H x L: 122 x 122 x 80 mm
• Protection: IP 65 IEC 60529
• Operating
temperature: -20...+70 °C
(without dew)
• Connection: 3x cable gland
M20x1,5
4x cable gland
M16x1,5
HEAG 173, HEAG 174, HEAG 175,
HEAG 176
• Dimensions
W x H x L: 50 x 75 x 55 mm
• Protection: IP 20 IEC 60529
• Operating
temperature: -20...+50 °C
(without dew)
• Connection: 3x screw terminal
connector
Connector (VL, ST
or SMA)
9 Technical data