10 Technical data
10.1 Technical data - electrical ratings
• Voltagesupply: 9...30VDC
• Consumptionw/oload: ≤100mA(perinterfaceSSI)
≤250mA(perinterfacebus)
• Initializingtime: ≤200msafterpoweron
• Interfaces: SSI,Probus-DPV0,CANopen®,DeviceNet
• Function: Multiturn
• Transmissionrate: 9.6...12000kBaud(Probus)
10...1000kBaud(CANopen®)
125...500kBaud(DeviceNet)
• Proleconformity: Probus-DPV0
CANopen®CiADSP406V3.0
DeviceProleEncoderV1.0
• Deviceadress: Rotaryswitchinbuscover
• Stepsperturn: 8192/13bit
• Numberofturns: ≤65536/16bit
• Additionaloutputsignals: Square-waveTTL(RS422)
Square-waveHTL
• Sensingmethod: Optical
• Code: Gray(versionSSI)
• Codesequence: CWdefault
• Inputs: SSIclock(versionSSI)
• Interferenceimmunity: EN61000-6-2:2005
• Emittedinterference: EN61000-6-3:2007/A1:2011
• Programmableparameters: Dependingontheselectedabsoluteinterface
• Diagnosticfunction: Positionorparametererror
• Statusindicator: DUO-LEDintegratedinbuscover
• Approvals: CE,ULapproval/E256710