Baumer ZADM 034I220.0022 User Manual

Browse online or download User Manual for Sensors Baumer ZADM 034I220.0022. Baumer ZADM 034I220.0022 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
11007447
Í?+ÂjOÂÂ*ÂPÎ
1/4
Canada
Baumer Inc.
CA-Burlington, ON L7M 4B9
Phone +1 (1)905 335-8444
China
Baumer (China) Co., Ltd.
CN-201612 Shanghai
Phone +86 (0)21 6768 7095
Denmark
Baumer A/S
DK-8210 Aarhus V
Phone +45 (0)8931 7611
France
Baumer SAS
FR-74250 Fillinges
Phone +33 (0)450 392 466
Germany
Baumer GmbH
DE-61169 Friedberg
Phone +49 (0)6031 60 07 0
India
Baumer India Private Limited
IN-411038 Pune
Phone +91 20 2528 6833/34
Italy
Baumer Italia S.r.l.
IT-20090 Assago, MI
Phone +39 (0)2 45 70 60 65
Singapore
Baumer (Singapore) Pte. Ltd.
SG-339412 Singapore
Phone +65 6396 4131
Sweden
Baumer A/S
SE-56133 Huskvarna
Phone +46 (0)36 13 94 30
Switzerland
Baumer Electric AG
CH-8501 Frauenfeld
Phone +41 (0)52 728 1313
United Kingdom
Baumer Ltd.
GB-Watchfield, Swindon, SN6 8TZ
Phone +44 (0)1793 783 839
USA
Baumer Ltd.
US-Southington, CT 06489
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
IND. CONT. EQ.
1DD2
Line sensor, analog
ZADM 034I220.0022
36
25
34 16,5
7,7
7 67
4,5
8,2ø
4,3ø
M8 x 1
5,3
5,5
Messfeldgrösse Size of measuring field Plage de mesure
Messfrequenz Measuring frequency Fréquenze de mesure
Ansprechzeit Response time Temps d'activation
Kleinstes Objekt Smallest recognizable object Object plus petit à reconnaître
Auflösung Resolution Résolution
Wiederholgenauigkeit Repeatability Reproductibilité
Linearitätsabweichung Linearity error Déviation de linéarité
Analogausgang Analog output Sortie de lumière
Lichtquelle Light source Source de lumière
Wellenlänge Wave length Longeur d'onde
Betriebsspannungsbereich +Vs (UL-Class 2) Voltage supply range +Vs (UL-Class 2) Plage de tension +Vs (UL-Class 2)
Max. Stromverbrauch Max. supply current Consommation max.
Kurzschlussfest Short circuit protection Protégé contre courts-circuits
Verpolungsfest Reverse polarity protection Protégé contre inversion de polarité
Arbeitstemperaturbereich Operating temperature range Température en service
Schutzklasse Protection class Classe de protection
22x200 mm
> 1100 Hz
< 0,9 ms
3 mm
< 0,1 mm (S=0...150mm)
< 0,2 mm (S=150...200mm)
< 0,1 mm (S=0...150mm)
< 0,2 mm (S=150...200mm)
< ± 1,75 mm (S=0...200mm)
< ± 1 mm (S=50...150mm)
4...20 mA
IR_LED
880 nm
12...28 VDC
120 mA
ja / yes / oui
ja / yes / oui*
0...+55 °C
IP 67
Page view 0
1 2 3 4

Summary of Contents

Page 1 - ZADM 034I220.0022

11007447Í?+ÂjOÂÂ*ÂPÎ1/4CanadaBaumer Inc.CA-Burlington, ON L7M 4B9Phone +1 (1)905 335-8444China Baumer (China) Co., Ltd.CN-201612 ShanghaiPhone +86 (0)

Page 2

2/4SummenmessungDer Sensor summiert die dunklen Flächen im Messbereich.Ganzer Messbereich abgedeckt -> Analogausgang = 20 mAGanzer Messbere

Page 3

3/4Summenmode, OFF = Kantenmodesum mode, OFF = edge modesomme mode, off = détection de bordSummenmode; OFF = Kantenmode).KantenmodeSummenmode=sum mode

Page 4

4/4When the analog output shows 4 mA, the reflective tape is in the rightposition, otherwise the output shows a value > 4 mA.ZADM 034I220.0022