PCD41
www.baumer.com 13
9. Programming plan
Zl 11-16 Status for Line 1-6
0 * Parameter can be changed
1 Clearing and/or input disabled
2 Parameter is skipped
Line 23 Input logic for control inputs
0 * Operating threshold 6 V
1 Operating threshold 3 V
Line 24 Decimal point for tachometer F
0 * No decimal point
1 00000.0
2 0000.00
3 000.000
Line 26 Offset
0 * No offset
1 Offset 2V/4mA without monitoring < 2V
2 Offset 2V/4mA with monitoring < 2V
Line 28 Update time (repeated display)
0 0,1 s
1 0,5 s
2 * 1 s
3 2 s
4 3 s
5 5 s
6 10 s
7 20 s
8 30 s
9 60 s
Line 31 Function of control input 1
0 * Hold
1 Reset maximum-value memory
2 Programming disable
3 Keylock
4 Print
Line 32 Function of control input 2
0 Hold
1 * Reset maximum-value memory
2 Programming disable
3 Keylock
4 Print
Line 33 Allotment output P1
0 * Top limit value tachometer
1 Bottom limit value tachometer
Line 34 Allotment output P2
0 * Top limit value tachometer
1 Bottom limit value tachometer
Line 35 Output logic for relay outputs
0 * Both outputs as normally open
1 Out 1 normally closed, Out 2 normally open
2 Out 1 normally open, Out 2 normally closed
3 Both outputs as normally closed
Line 39 Hold delay time
0 * No delay
1 Delay 1 s
:
4 Delay 9 s
Line 40 Code setting
0000 * Code not active
:
9999
Line 51 Baud rate
0 * 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 52 Parity
0 * Even
1 Odd
2 No
Line 53 Stop bits
0 * 1 stop bit
1 2 stop bits
Line 54 Device address
00 * Minimum value
:
99 Maximum value
Line 55 Allotment output value via interface
0 * F
1 SZ
Line 56 RS422: Control connections TxD+,TxD-
0 * switched in sense of transmission for
transmission, in sense of reception for
reception
1 Always in sense of transmission
Page view 12