3.4. Inclination sensor profile
3.4.1. Inclination sensor object overview
According to CiA (CAN in Automation) the objects are subdivided into three groups:
Standard objects:
1000h, 1001h, 1018h
Manufacturer-specific objects:
2000h - 5FFFh
Device-specific objects:
All remaining objects from 1000h - 1FFFh, 6000h - FFFFh
The table below is giving a summary of all SDO objects supported by the inclination sensor.
Object Object number in Hex
Name ---
Format U/I = Unsigned/Integer, number = number bit, ARR = Array, REC = Record
Access ro = ReadOnly, wo = WriteOnly, rw = ReadWrite
Default Default upon first init or restore default
Save yes saved in EEPROM
Meaning supplementary description
Object
Sub-Index
Name
Format
Access
Default
Save
Meaning
1000h
Device Type
U32
ro
0004019Ah
0x019A = 410 = device profile inclination
sensor
0x0004 = Two axis with resolution max.
32-bit
1001h
Error Register
U8
ro
0h
Bit0 = Generic error
Bit4 = Communication error (overrun, …)
Bit7 = Manufacturer -specific
1003h
PreDefined
ErrorField
ARR
Comprises the last 8 errors or warnings
00h
Maximum Subindex
U8
rw
0h
ja
Number of messages saved (0..8)
01h
Latest entry
U32
ro
Latest error or warning
1000h Generic Error
5530h EEPROM Error
6010h Software Reset (Watchdog)
7510h Internal Communication Error
8130h Life Guard Error or Heartbeat Error
..
..
..
..
..
..
08h
Oldest entry
U32
ro
Error or warning, see Sub-Index 01h
1005h
Sync COB-ID
U32
rw
80h
ja
COB-ID of Sync Oject
1008h
DeviceName
U32
ro
"GNAM"
Device name
GNAMG inclination sensor
1009h
Hardware Version
U32
ro
werkseitig
Product Hardware Version in ASCII
100Ah
Software Version
U32
ro
werkseitig
Product Software Version in ASCII
100Ch
Guard Time
U16
rw
0h
ja
Timer Nodeguarding
100Dh
Life Time factor
U8
rw
0h
ja
Guard Time Multiplier
1010h
Store Parameters
ARR
00h
Maximum Subindex
U8
ro
4h
01h
Save all parameters
U32
rw
=“save“ (0x73617665) to save
02h
Communication
parameters
U32
rw
=“save“ (0x73617665) to save
03h
Application
parameters
U32
rw
=“save“ (0x73617665) to save
04h
Manufacturer-
specific parameters
U32
rw
=“save“ (0x73617665) to save
1011h
Restore Default
Parameters
ARR
00h
Größter Subindex
U8
ro
4h
01h
Alle Parameter
U32
rw
=“load“ (0x6C6F6164) to load