Summary of Contents

Page 1 - Capteur de distance laser

Manual_OADM20x659_DE_EN.doc 1/48 Baumer 04.12.12 Frauenfeld, Switzerland Bedienungshandbuch / User Manual / Manuel d'utilisation Laser-

Page 2 - English

Manual_OADM20x659_DE_EN.doc 10/48 Baumer 04.12.12 Frauenfeld, Switzerland Was tun bei teiltransparenten, glasklaren und spiegelnden Messobjekten?

Page 3 - 1 Allgemeine Hinweise

Manual_OADM20x659_DE_EN.doc 11/48 Baumer 04.12.12 Frauenfeld, Switzerland 5 Messbereich teachen Jeder Sensor wird mit dem im Datenblatt angegeben

Page 4 - 3 Montage

Manual_OADM20x659_DE_EN.doc 12/48 Baumer 04.12.12 Frauenfeld, Switzerland OADM 20I6591 Typische Auflösung Typische Linearitätsabweichung Sr =

Page 5 - 3.1 Montagehinweise

Manual_OADM20x659_DE_EN.doc 13/48 Baumer 04.12.12 Frauenfeld, Switzerland OADM 20I6593 Typische Auflösung Typische Linearitätsabweichung Sr = g

Page 6

Manual_OADM20x659_DE_EN.doc 14/48 Baumer 04.12.12 Frauenfeld, Switzerland 5.1 Messbereich teachen mit der Teach-Taste Einstellen eines neuen Mess

Page 7

Manual_OADM20x659_DE_EN.doc 15/48 Baumer 04.12.12 Frauenfeld, Switzerland 5.2 Fabrikzustand herstellen mit der Teach-Taste Innerhalb von 5 Minute

Page 8 - 3.2 Definition des Messfeld

Manual_OADM20x659_DE_EN.doc 16/48 Baumer 04.12.12 Frauenfeld, Switzerland Verzögerung zwischen Teachsignal und Quittierung am Alarmausgang: Ei

Page 9 - 4 Anwendungshinweise

Manual_OADM20x659_DE_EN.doc 17/48 Baumer 04.12.12 Frauenfeld, Switzerland Zeit Beschreibung Wert Kommentar t1 Mindestdauer Tastendruck 5 s B

Page 10

Manual_OADM20x659_DE_EN.doc 18/48 Baumer 04.12.12 Frauenfeld, Switzerland 6 Alarmausgang Der Alarmausgang wird gesetzt, wenn das Objekt ausserha

Page 11 - 5 Messbereich teachen

Manual_OADM20x659_DE_EN.doc 19/48 Baumer 04.12.12 Frauenfeld, Switzerland Mehrere Sensoren miteinander synchroniseren Über einen externen Takt kön

Page 12 - OADM 20I6592

Manual_OADM20x659_DE_EN.doc 2/48 Baumer 04.12.12 Frauenfeld, Switzerland Deutsch 1 Allgemeine Hinweise ...

Page 13 - OADM 20I6593

Manual_OADM20x659_DE_EN.doc 20/48 Baumer 04.12.12 Frauenfeld, Switzerland Sensor t1 t2 OADM 20I6591 < 2 ms 1.5 ... 6 ms OADM 20I6592 <

Page 14

Manual_OADM20x659_DE_EN.doc 21/48 Baumer 04.12.12 Frauenfeld, Switzerland 8 Technische Daten OADM 20I… …6591 …6592 …6593 Messbereich MB 50…30

Page 15

Manual_OADM20x659_DE_EN.doc 22/48 Baumer 04.12.12 Frauenfeld, Switzerland *1) und *2) Auflösung und Linearitätsabweichungen gemessen auf weisse K

Page 16

Manual_OADM20x659_DE_EN.doc 23/48 Baumer 04.12.12 Frauenfeld, Switzerland 9 Anschluss Anschlussbelegung 10 Erdungskonzept Um einen o

Page 17 - Manual_OADM20x659_DE_EN.doc

Manual_OADM20x659_DE_EN.doc 24/48 Baumer 04.12.12 Frauenfeld, Switzerland 12 Zubehör Befestigungswinkel Art.-Nr. 10131521, Befestigungswinkel au

Page 18 - 6 Alarmausgang

Manual_OADM20x659_DE_EN.doc 25/48 Baumer 04.12.12 Frauenfeld, Switzerland User Manual Laser distance sensor series OADM 20I659...

Page 19

Manual_OADM20x659_DE_EN.doc 26/48 Baumer 04.12.12 Frauenfeld, Switzerland 1 General notes Rules for proper usage This product is a precision de

Page 20

Manual_OADM20x659_DE_EN.doc 27/48 Baumer 04.12.12 Frauenfeld, Switzerland 2 Functional principle The distance measured is based on the triangulat

Page 21 - 8 Technische Daten

Manual_OADM20x659_DE_EN.doc 28/48 Baumer 04.12.12 Frauenfeld, Switzerland Steps / edges: When measuring right next to steps / edges, it

Page 22

Manual_OADM20x659_DE_EN.doc 29/48 Baumer 04.12.12 Frauenfeld, Switzerland Shiny objects with a constant structure Especially shiny objects with a

Page 23 - 11 Wartungshinweise

Manual_OADM20x659_DE_EN.doc 3/48 Baumer 04.12.12 Frauenfeld, Switzerland 1 Allgemeine Hinweise Bestimmungsgemässer Gebrauch Dieses Produkt ist ei

Page 24 - 12 Zubehör

Manual_OADM20x659_DE_EN.doc 30/48 Baumer 04.12.12 Frauenfeld, Switzerland Ambient light: The OADM Series ... 20I659 was optimized in ambient light

Page 25

Manual_OADM20x659_DE_EN.doc 31/48 Baumer 04.12.12 Frauenfeld, Switzerland 3.1 Measuring field OADM 20 OADM 20I6591 OA

Page 26 - 1 General notes

Manual_OADM20x659_DE_EN.doc 32/48 Baumer 04.12.12 Frauenfeld, Switzerland 4 Application hints To reach the maximum accuracy of OADM 20I659.. ser

Page 27 - 3 Mounting instructions

Manual_OADM20x659_DE_EN.doc 33/48 Baumer 04.12.12 Frauenfeld, Switzerland What can you do if you have transparent, semi-transparent and highly ref

Page 28 - 10 -15°

Manual_OADM20x659_DE_EN.doc 34/48 Baumer 04.12.12 Frauenfeld, Switzerland 5 Teaching the OADM Every sensor is delivered with the factory setup (

Page 29

Manual_OADM20x659_DE_EN.doc 35/48 Baumer 04.12.12 Frauenfeld, Switzerland OADM 20I6591 Typical resolution: Typical linearity error: Sr = taught

Page 30

Manual_OADM20x659_DE_EN.doc 36/48 Baumer 04.12.12 Frauenfeld, Switzerland OADM 20I6593 Typical resolution: Typical linearity error: Sr = taught

Page 31 - 3.1 Measuring field OADM 20

Manual_OADM20x659_DE_EN.doc 37/48 Baumer 04.12.12 Frauenfeld, Switzerland 5.1 How to teach a new range using the teach button Teaching a new meas

Page 32 - 4 Application hints

Manual_OADM20x659_DE_EN.doc 38/48 Baumer 04.12.12 Frauenfeld, Switzerland 5.2 How to reset the factory settings using the teach button Within 5 m

Page 33

Manual_OADM20x659_DE_EN.doc 39/48 Baumer 04.12.12 Frauenfeld, Switzerland Delay between teach signal and response on alarm output: Input circui

Page 34 - 5 Teaching the OADM

Manual_OADM20x659_DE_EN.doc 4/48 Baumer 04.12.12 Frauenfeld, Switzerland 2 Funktionsprinzip Die Distanzmessung basiert auf dem Triangulationsprin

Page 35

Manual_OADM20x659_DE_EN.doc 40/48 Baumer 04.12.12 Frauenfeld, Switzerland Time Description of timing functions Value Comment t1 Minimum button

Page 36

Manual_OADM20x659_DE_EN.doc 41/48 Baumer 04.12.12 Frauenfeld, Switzerland 6 Alarm output The alarm output indicates when an object is outside the

Page 37

Manual_OADM20x659_DE_EN.doc 42/48 Baumer 04.12.12 Frauenfeld, Switzerland Synchronizing several sensors Several sensors may be synchronized using

Page 38

Manual_OADM20x659_DE_EN.doc 43/48 Baumer 04.12.12 Frauenfeld, Switzerland Sensor t1 t2 OADM 20I6591 < 2 ms 1.5 ... 6 ms OADM 20I6592 <

Page 39

Manual_OADM20x659_DE_EN.doc 44/48 Baumer 04.12.12 Frauenfeld, Switzerland 8 Technical data OADM 20I… …6591 …6592 …6593 Measuring range MR 5

Page 40

Manual_OADM20x659_DE_EN.doc 45/48 Baumer 04.12.12 Frauenfeld, Switzerland *1) and *2) measured on white ceramic sheet *3) the response time depend

Page 41 - 7 Synchronization input

Manual_OADM20x659_DE_EN.doc 46/48 Baumer 04.12.12 Frauenfeld, Switzerland 10 Grounding concept For maximum EMC protection and reliable application

Page 42

Manual_OADM20x659_DE_EN.doc 47/48 Baumer 04.12.12 Frauenfeld, Switzerland 13 Troubleshooting Error Possible reason Correction The sensor does no

Page 43

Manual_OADM20x659_DE_EN.doc 48/48 Baumer 04.12.12 Frauenfeld, Switzerland Brasil Baumer do Brasil Ltda BR-04726-001 São Paulo-Capital Phone +55

Page 44 - 8 Technical data

Manual_OADM20x659_DE_EN.doc 5/48 Baumer 04.12.12 Frauenfeld, Switzerland 3.1 Montagehinweise Stufen / Kanten: Wird unmittelbar neben Stufen/Kant

Page 45

Manual_OADM20x659_DE_EN.doc 6/48 Baumer 04.12.12 Frauenfeld, Switzerland Glänzende Messobjekte mit gleichmässig ausgerichteter Struktur: Besonders

Page 46 - 12 Accessories

Manual_OADM20x659_DE_EN.doc 7/48 Baumer 04.12.12 Frauenfeld, Switzerland Fremdlicht: Die Serie OADM 20I659… wurde speziell im Bereich Fremdlichtsi

Page 47 - 13 Troubleshooting

Manual_OADM20x659_DE_EN.doc 8/48 Baumer 04.12.12 Frauenfeld, Switzerland 3.2 Definition des Messfeld OADM 20I6591 OADM

Page 48

Manual_OADM20x659_DE_EN.doc 9/48 Baumer 04.12.12 Frauenfeld, Switzerland 4 Anwendungshinweise Die Laser Distanz Sensoren der Serie OADM 20I659… s

Comments to this Manuals

No comments